<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Tecnova HT &#8211; FORTEK</title>
	<atom:link href="https://fortek.marcoperez.consulting/en/brand/tecnova-ht-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://fortek.marcoperez.consulting/en/</link>
	<description>Fornitura, Prodotti e Servizi per l&#039;industria</description>
	<lastBuildDate>Mon, 02 May 2022 09:39:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://fortek.marcoperez.consulting/wp-content/uploads/2021/10/cropped-logo-fortek-32x32.png</url>
	<title>Tecnova HT &#8211; FORTEK</title>
	<link>https://fortek.marcoperez.consulting/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Photometric analyzers</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/photometric-analyzers/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:40 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6574</guid>

					<description><![CDATA[<p>The Optek photometric analyzers are suitable for inline analysis and for concentration, color, and turbidity analysis and exploit the interaction between light and the process (liquid or gaseous): a ray of light penetrates the heart of the process while a photoelectric silicon cell measures the intensity of the resultant light. The Optek analysis systems consist of [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/photometric-analyzers/">Photometric analyzers</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The<strong> Optek</strong> photometric analyzers are suitable for inline analysis and for concentration, color, and turbidity analysis and exploit the interaction between light and the process (liquid or gaseous): a ray of light penetrates the heart of the process while a photoelectric silicon cell measures the intensity of the resultant light.</p>
<p>The <strong>Optek analysis systems</strong> consist of three elements:</p>
<ul>
<li>Converter/Transmitter</li>
<li>Sensor: Inline or insertion, including the light source and the photoelectric cell</li>
<li>CableSet: Industrial shielded cable connecing the sensor to the converter</li>
</ul>
<p>The <strong>Optek photometric analyzers</strong> are suitable for many applications in the chemical sector, petrochemical and refineries, biotechnology, food industry and beer, paper industry.</p>
<p>The most common uses are:</p>
<ul>
<li>Monitoring contaminated liquids in the distillate</li>
<li>Continuous analysis of halogens</li>
<li>Fermentation and biomass growth in the laboratory and pilot plant</li>
<li>Color and quality monitoring</li>
<li>Color and variation of color during the synthesis or in the final product</li>
<li>Concentration of any solid in liquid solvent</li>
<li>Ultrafiltration on the permeate and the retentate</li>
</ul>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/photometric-analyzers/">Photometric analyzers</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LIQUISONIC® &#8211; Ultrasonic analyzer for liquid density and concentration measurement</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/liquisonic-ultrasonic-analyzer-for-liquid-density-and-concentration-measurement/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:40 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6575</guid>

					<description><![CDATA[<p>LiquiSonic® Sensotech measures inline the concentration or density in almost every kind of liquid. The technology is based on a high-precision measurement and a very fast and stable analytical method, that is independent of conductivity, colour and transparency of the process liquids. LIQUISONIC® SensoTech is an analyzer for on-line measurement of the liquid concentration. It [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/liquisonic-ultrasonic-analyzer-for-liquid-density-and-concentration-measurement/">LIQUISONIC® &#8211; Ultrasonic analyzer for liquid density and concentration measurement</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>LiquiSonic® Sensotech</strong> measures inline the concentration or density in almost every kind of liquid. The technology is based on a high-precision measurement and a very fast and stable analytical method, that is independent of conductivity, colour and transparency of the process liquids.</p>
<p><strong>LIQUISONIC® SensoTech</strong> is an analyzer for on-line measurement of the liquid concentration. It works through the ultrasonic principle, whose operation is based on the concept of Sonic Absolute Speed or the propagation of sound waves in the medium (gas, liquid or solid).</p>
<p><strong>LIQUISONIC®</strong> is made of a sonic waves emitter with a frequency of &gt; 1 MHz and a receiver, both immersed in the liquid, which carry out a averaged measurement 32 times per second. Since the Sonic speed requires an accurate temperature compensation, <strong>LIQUISONIC®</strong> is provided with two Pt1000 temperature sensors embedded in the steel of the prongs, as well as analog inputs for measuring the pressure in line from the field or from DCS. Both electronics and the sensor in contact with the process are available in multiple variants, even maintaining the standard features of the<strong> LIQUISONIC®</strong> system:</p>
<ul>
<li>Absolute sonic speed, concentration and density measurement in liquid phase and continuous</li>
<li>Suitable for Vs from 100 to 10,000 m / sec and Top -90 to + 200 ° C, Pop as a rating for the selected flange</li>
<li>Accuracy of 0.05 m/sec for the speed and 0.1 °C for the temperature</li>
<li>The measure is not dependent on conductivity or fluid transparency</li>
<li>Can be installed in tanks, reactors, process lines, both vertical and horizontal bypass</li>
<li>No moving parts or seals or O-rings to maintain over time</li>
<li>The sensors are suitable for CIP and SIP procedures</li>
<li>Auto-compensation for the aging of electronic parts or sensors</li>
<li>Up to 256 Dataset</li>
<li>HMI panel with high visibility TFT video and clear and well-structured tree menu</li>
<li>Incorporated Events Recorder in accordance with FDA 21 CFR Part 11</li>
<li>4-20 mA outputs, RS232 and Fieldbus</li>
<li>Up to 4 sensors are connectable with 1 electronic for 4 simultaneous analysis</li>
<li>Remote Service via modem from the parent company</li>
<li>SonicWorkTM Software for comprehensive management of the system, records, diagnostics, and settings</li>
<li>EC  ATEX Certificate II 2 G Ex de IIC T3, T4, T5 or T6 for Zones 2, 1, 0.</li>
</ul>
<hr />
<p>Depending on the severity of the application, the LIQUISONIC® system can be supplied in different versions:</p>
<p>&#8211; <strong>Liquisonic® 30</strong> &#8211; for all applications<br />
&#8211;<strong> Liquisonic® 20</strong> &#8211; light version for OEM or basic applications<br />
&#8211; <strong>Liquisonic® 40</strong> &#8211; to calculate two different concentrations with ternary mixtures<br />
&#8211; <strong>Liquisonic® 50</strong> &#8211; for crystallization and polymerization processes<br />
&#8211; <strong>Liquisonic® Lab</strong> &#8211; extremely flexible portable version</p>
<p>It is also available in a wide range of materials for the sensors in contact with the process: Stainless Steel, SS polished, electropolished SS, Hastelloy B-3 / C-4 / C-2000, Incoloy 825, Nickel 200, Monel 400, Titanium Titanium / Palladium, Tantalum, Zirconium 702, Linings PFA / Halar® / Tantalum &#8230;</p>
<hr />
<p><strong>APPLICATIONS</strong></p>
<ul>
<li>Beer Industry</li>
<li>Biotechnology (crystallization, fermentation, filtration, HPLC)</li>
<li>Steel industry</li>
<li>Chemical Industry</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/liquisonic-ultrasonic-analyzer-for-liquid-density-and-concentration-measurement/">LIQUISONIC® &#8211; Ultrasonic analyzer for liquid density and concentration measurement</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>BOD, TOC, COD TNb, TP, Toxicity analyzers</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/bod-toc-cod-tnb-tp-toxicity-analyzers/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:40 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6576</guid>

					<description><![CDATA[<p>QuickTOC Ultra® is an industrial analyzer for on-line and continuous measurement of Total Carbon (TC) and Dissolved Organic Carbon (DOC) according to DIN EN 1484: 1997-08, ISO 8254: 1999-03, EPA 415.1. It is possible to combine it with TNb and COD. QuickTOC Ultra® uses as a principle of measuring the pure thermal oxidation at 1200 °C, [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/bod-toc-cod-tnb-tp-toxicity-analyzers/">BOD, TOC, COD TNb, TP, Toxicity analyzers</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>QuickTOC Ultra®</strong> is an <strong>industrial analyzer</strong> for on-line and continuous measurement of <strong>Total Carbon (TC)</strong> and <strong>Dissolved Organic Carbon (DOC)</strong> according to DIN EN 1484: 1997-08, ISO 8254: 1999-03, EPA 415.1. It is possible to combine it with <strong>TNb </strong>and<strong> COD.</strong></p>
<p>QuickTOC Ultra® uses as a principle of measuring the <strong>pure thermal oxidation at 1200 °C</strong>, while the part of the sample adduction exploits the FlowSampler® technology of 32 mm tubes, thus avoiding repeated cleaning and daily mandatory long service.</p>
<p>The continuous analysis technology consists of a set of microbatches alternating with self-cleaning and allows, thanks to the analysis-end signal, to implement multi-stream applications. It is also possible to analyze with high salt concentration due to thermal oxidation and patented furnace without the need to pre-treat the sample.</p>
<ul>
<li>Size, weight and classification: 1020 x 700 x 520 mm (W x H x D), 115 kg, IP54, also NEMA 4X / IP66 and certified for hazardous zone 1 and 2.</li>
<li>Measuring range: 0.1-200; 2-400; 5-2.000; 10-15,000; 500 to 50.000 mg / l TOC</li>
</ul>
<hr />
<p><strong>QuickTOC® Loop</strong> is identical to QuickTOC® as regards the part of the thermal combustion at 1200 °C. Its part of injection in the sample is not robotic and it is fixed directly in the furnace. As it doesn’t have any moving part, this analyzer is suitable for analysis of great precision for lower fields. It provides for native multistream up to 6 points of analysis. QuickTOC®loop can be supplied in different models.</p>
<p><strong>QuickTOC® Purity</strong> can be used in any industry where the use of pure water and ultrapure water is necessary to prevent the contamination of expensive processes with high added value, to ensure the safety of the surrounding area and high quality of the final product. Measuring range: 10 to 2.000 mg / l, 0:01 &#8211; 10 mg / l. Other ranges are available on request.</p>
<p><strong>QuickTOC® Condensate</strong> <strong>&#8211; Condensed Network security</strong> is an analyzer of thermal oxidation @ 1200 °C with loop methodology and consists of a boiler that produces saturated steam which, once overheated, can be used in the process or sent to the turbine for the production of energy. Measuring range: 10 to 2.000 mg / l, 0.1 &#8211; 10/20 mg / l.</p>
<p><strong>QuickTOC® Pharma</strong> has all the technical characteristics of the loop line but is designed for the pharmaceutical industry. It is an inline analyzer intended to calculate the TOC for Ultrapure Water and Water for Injection according to USP Chapter 643 and EP 2.2.44. Measuring range: 10 to 2.000 mg / l.</p>
<p><strong>QuickTOC® UV</strong> is an in line and continuous analyzer for the measurement of TC, TOC or DOC and operates through the Photochemical Oxidation. QuickTOC®uv is in accordance with DIN EN 1484: 1997-08, US-EPA standard and is also available for dual channel use. It is also provided with self-calibration, AutoStart, and can be supplied with ambient air treatment to produce the carrier car gar necessary, humidity sensor and pressure sensor. Measuring range; 0.1 &#8211; 1,000 mg / l. Other ranges available on request. Size, weight and classification: 746 x 600 x 420 mm (W x H x D), 70 kg, IP54 / IP65, also for Zone 1 and Zone 2.</p>
<p><strong>QuickCOD Ultra®</strong> is an in line and continuous analyzer combining the TC and the COD measurements.</p>
<p><strong>QuickCOD Ultra®_i</strong> complies with all technical features of the QuickTOC® and computes the COD by mathematical correlation with the TOC. It is also able to calculate COD and Total Nitrogen simultaneously, it is multistream and has certification for hazardous Zone 1 and 2.</p>
<p><strong>QuickCOD Ultra®_o</strong> is an analyzer using the principle of thermal oxidation at 1200 °C and is equipped with an analysis system according to ASTM D 6238-98 &#8220;Standard Test Method for Total Oxygen Demand in Water&#8221;. It is also able to calculate COD and Total Nitrogen simultaneously, it is multistream and has certification for hazardous Zone 1 and 2. Measuring range: 10-150, 100-2000, 500-5000, 1000-8000, from 20,000 to 250,000 mg/l.</p>
<p>The whole <strong>QuickCOD Ultra® line</strong> has the following size, weight and classification: 1020 x 700 x 520 mm (W x H x D), 115 kg, IP54, also NEMA 4X / IP66.</p>
<p><strong>Elox100®</strong> is an analyzer based on the electrochemical oxidation of the sample by the action of the electric current on a special electrode allowing to observe any peak of the COD. <strong>Elox100®</strong> is provided with the FlowSampler® technology without filtration and ensures continuous analysis without catalysts and with no moving parts. <strong>Elox100®</strong> is equipped with backlit graphic display with self-guided menus for settings and maintenance, as well as IP55 / NEMA 13 or IP65 / NEMA 4X enclosure. Dimensions and weight: 600 x 600 x 420 mm (W x H x D), 45 kg. Measuring range: 1 to 100,000 mg/l COD.</p>
<p><strong>QuickTON Ultra®</strong> is an inline analyzer for measuring Total Nitrogen (TNb) according to DIN EN 12260: 2003 and ISO / TR 11905-2: 1997. It is intended for applications involving the entry and exit processes in water treatment. In addition to the ability of supporting the TOC and COD in multistreams, the <strong>QuickTON Ultra® system</strong> is designed on the basis of a furnace at 1200 °C without catalysts and is provided with a section dedicated to the analysis of NO flowing from the reactor. You can obtain a measurement in Chemiluminescence CLD or with a ECD integrated sensor or you can measure the concentration of NO which generates the Total Nitrogen. <strong>QuickTON Ultra®</strong> is also suitable in case of high salt concentration and exploits the<strong> FlowSampler®</strong> technology without filtration, ensuring continuous analysis without catalysts and with no moving parts. Measuring range: 0-200 mg/l.</p>
<p>The whole <strong>QuickTON® series</strong> has the following size, weight and classification: 1020 x 700 x 520 mm (W x H x D), 115 kg, IP54, NEMA 4X / IP66 ATEX certified for Zone 1 and Zone 2.</p>
<p><strong>QuickTOCNPO®</strong> allows a multiparametric analysis and is able to simultaneously manage the Total Phosphorus (TP), the Total Organic Carbon (TOC), the Total Nitrogen (TNb) and the Chemical Oxygen Demand (COD) according to DIN EN ISO 6878: 2004-09 (TP), DIN EN ISO 15681-1: 2005 (TP) and DIN EN ISO 15681-1: 2005-05 (TP). Measuring range: 0.1 &#8211; 50 mg / l (TNb); 0.1 to 200 mg / l (TOC); 0.01 to 4 mg / l (TP); 1-600 mg / l (COD).</p>
<p>The QuickTOCNPO® series presents the following size, weight and classification: 1020 x 700 x 520 mm (W x H x D), 115 kg, IP54, NEMA 4X / IP66 ATEX certified for Zone 1 and 2.</p>
<p><strong>ToxAlarm</strong> is an inline analyzer which allows to determine the level of toxicity in the treated water after WWT according to DIN EN ISO 9509: 2006. The measuring principle of<strong> ToxAlarm</strong> is based on the inhibition of the respiration of the bacteria as a low consumption of oxygen by the biomass indicates the presence of toxic substances.<strong> ToxAlarm</strong> is provided with graphic LCD screen and automatic StartUp. Measuring range: 0-100%. Size, weight and classification: 870 x 600 x 560 mm (H x W x D), 70 kg, IP54, NEMA 4X / IP65 ATEX certified for Zone 1 and 2.</p>
<p><strong>Hydronova 2010</strong> and <strong>Portable Hydronova 2010</strong> are inline photometric and colorimetric analyzers using official IRSA recognized procedures. They can measure parameters such as: iron, copper, silicates, sulfites, cyanides, chlorine, chloride, ionic, nitrates, surfactants, phosphates, magnesium, zinc and more. They also ensure easy programming of the analysis cycle with auto-calibration and self-cleaning. Measuring range: dependent on the required parameter and methodical choice in the order of ppm. Dimensions and weight: 145 x 60 x 40 c (H x W x D), 65 kg (Hydronova 2010); 80 x 60 x 30 cm (H x W x D), 30 kg (Portable Hydronova 2010).</p>
<p>&nbsp;</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/bod-toc-cod-tnb-tp-toxicity-analyzers/">BOD, TOC, COD TNb, TP, Toxicity analyzers</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Refractometers for liquid phase analysis</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/refractometers-for-liquid-phase-analysis/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:40 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6577</guid>

					<description><![CDATA[<p>The PR 23 KPATENTS series represents the top of quality and reliability in the field of the analysis of the concentration in the liquid phase using a refractometer, thanks to some features such as the absence of moving parts, the traceability of the laboratory standards, the lack of drift due to digital measurement, the variety of solutions [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/refractometers-for-liquid-phase-analysis/">Refractometers for liquid phase analysis</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The<strong> PR 23 KPATENTS series</strong> represents the top of quality and reliability in the field of the <strong>analysis of the concentration in the liquid phase using a refractometer,</strong> thanks to some<strong> </strong>features such as the absence of moving parts, the traceability of the laboratory standards, the lack of drift due to digital measurement, the variety of solutions for all kinds of process or OEM.</p>
<p>The <strong>refractometric measurement system</strong> is based on the phenomenon of refraction and is able to generate numerous advantages since, for example, there is no interference generated by the color of the process or by the possible presence of particulate matter and bubbles.</p>
<p>The<strong> digital platform PR-23</strong> is provided with a series of standard features, and it is possible to customize the sensor in contact with the process.</p>
<p>The<strong> basic version PR-23-A</strong> provides:</p>
<ul>
<li>Range Refractive index nd = 1.3100 &#8211; 1.5400, equivalent to 0-100 Brix</li>
<li>Accuracy nd ± 0.0002 equal to ± 0.1% by weight</li>
<li>Digital Measurement via CCD 3648 pixels</li>
<li>Light Emitting Diode to 589 mm LED of Sodiod wavelength for a rapid comparison with the standard in the literature</li>
<li>Digital calibration at the factory with certified liquid Cargille on the whole range nd = 1.3100 &#8211; 1.5400</li>
<li>Patent CORE® Optics (US P / N 6,067,151 US): The optical is separated from the sensor electronics</li>
<li>Integrated Pt 1000 for compensation of non-linear conversion nd -&gt; Brix</li>
<li>Process connections 3A-Clamp Varivent®, custom flow cell &#8230;</li>
<li>Wetted parts in AISI 316L, Spinel (prism), PTFE (prism seals)</li>
<li>Process conditions suitable up to 15 barg @ 20° C or 120° C @ 9 barg</li>
<li>Even two channels ie two sensors managed independently from a transmitter</li>
<li>Certified versions ATEX IECEx  for Zone 2, Zone 1, Zone 0</li>
<li>Port 10/100 Base Ethernet and JAVA© Software incorporated into the transmitter for viewing and managing through the analyzer corporate LAN, even from remote locations</li>
</ul>
<hr />
<p>The <strong>PR-33-AC OEM series</strong> is intended for the market of manufacturers of machines, skid and compact systems for food and beverage. It is made of stand-alone sensors that do not require remote electronics and are equipped with connections to the 3A-Clamp, Varivent® process and custom flow cell.</p>
<p>The <strong>PR-23-AC PHARMA series</strong> presents the same technical features of the A series, but conforms to PAT, GMP, CIP / SIP, and 21 CFR Part 11 and Validations of pharmaceutical production protocols.</p>
<p>The <strong>PR-23-W / M series</strong> presents the same technical features of the A series, but is also equipped with a sensor suitable for strong acids and bases, as well as the possibility of extending the range nd = 1.2600 &#8211; 1.5000, 0-100 Brix.</p>
<p>The<strong> W Series</strong> is equipped with optics inserted into the valve body Saunders DN 2&#8243;, 3&#8243;, 4 &#8221; lined with PFA Fluorinated Ethylene Propylene, wetted parts of the sensor in PTFE, prism in Spinel or sapphire, prism seals in PTFE, while the <strong>M Series</strong> is equipped with optics inserted into a solid block in PTFE or Kynar®, prism in Spinel, O-rings in Kalrez, prism seals in Teflon®.</p>
<p>The <strong>Pr-23-GP series</strong> has the same technical characteristics of the AC series, but is equipped with heavy duty sensor type  Sandvik® Clamp or flanged ANSI / DIN / JIS and it is suitable for process conditions up to 25 barg and 150° C.</p>
<p>The <strong>PR-23-RP series</strong> is addressed to the Oil &amp; Gas market and is equipped with a one-piece sensor without any kind of welding and with connection to the process through flanging ANSI Rating # 300 for Design Pressures of up to 25 barg.</p>
<p>The <strong>PR-23-MS SEMICONDUCTOR series</strong> is designed for the semiconductors market for process applications. It presents the following characteristics:</p>
<ul>
<li>Expanded Range nd = 1.2600 &#8211; 1.5000 with sapphire prism H74 for analyzing hydrofluoric acid</li>
<li>Wetted parts and prism seals in modified PTFE, prism in Sapphire H73 or H74, O-rings in Kalrez, sensor body in stainless steel with epoxy paint coating</li>
<li>Flow cell integrated into the sensor to avoid contamination</li>
<li>Connections: Flare Fitting or Nippon Pillar Super 300 for DN ¼ &#8220;, ½&#8221;, ¾ &#8220;, 1&#8221;</li>
<li>Installation both horizontal and vertical</li>
<li>ATEX IECEx version available</li>
</ul>
<p>The<strong> PR-33-S SEMICONDUCTORS</strong> series presents the same technical characteristics of the AC Series but is designed for the market of manufacturers of machines, skid and compact systems for clean rooms. It has the following characteristics:</p>
<ul>
<li>Stand-alone sensor with no remote electronics</li>
<li>Expanded range nd  = 1.2600 &#8211; 1.5000, with prism H74 Sapphire for hydrofluoric acid analysis</li>
<li>Wetted parts and prism seals in modified PTFE, prism in Sapphire H73 (or H74), O-ring in Kalrez, sensor body in Ultra-pure Kynar® PVDF</li>
<li>Flow cell integrated into the sensor to avoid contamination</li>
<li>Process connections: Flare Fitting or Nippon Pilla Super 300 for DN ¼ &#8220;, ½&#8221;, ¾ &#8220;, 1&#8221;</li>
<li>Output 4-20 mA via Ethernet 10/100</li>
<li>JAVA Software © incorporated into the electronics of the sensor for viewing and managing through the analyzer corporate LAN, even from remote locations</li>
</ul>
<p>&nbsp;</p>
<p>The entire<strong> K-Patents series</strong> can be installed in many ways and is intended for multiple applications in several industries:</p>
<ul>
<li>Biochemistry and pharmaceutical</li>
<li>Basic chemicals</li>
<li>Food</li>
<li>Oil &amp; Gas</li>
<li>Semiconductors</li>
<li>Metals</li>
</ul>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/refractometers-for-liquid-phase-analysis/">Refractometers for liquid phase analysis</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermal Mass Flowmeters – Master-Touch MP – MPNH</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-master-touch-mp-mpnh/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:39 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6568</guid>

					<description><![CDATA[<p>The Thermal Mass Flowmeters measure the mass flow rate of the flowing gas without the aid of moving parts and are not susceptible to variations in pressure or process temperature. Thanks to the Thermal Mass technology, the Thermal Mass Flowmeters can measure the mass of the gas flow per unit time, without the influence of temperature and pressure on the meter. Each Thermal [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-master-touch-mp-mpnh/">Thermal Mass Flowmeters – Master-Touch MP – MPNH</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The<strong> Thermal Mass Flowmeters</strong> measure the mass flow rate of the flowing gas without the aid of moving parts and are not susceptible to variations in pressure or process temperature.</p>
<p>Thanks to the Thermal Mass technology, the <strong>Thermal Mass Flowmeters can measure</strong> the mass of the gas flow per unit time, without the influence of temperature and pressure on the meter.</p>
<p>Each <strong>Thermal Mass Flowmeter </strong>is calibrated to the required flow rate and pre-compensated for temperature.</p>
<p>The <strong>Thermal Mass Flowmeters</strong> are suitable for applications involving, among others: Argon, Nitrogen, Biogas, CO2, Digester, Helium, Gas Torch, hydrogen, hydrocarbon mixtures, Methane, Natural Gas, Oxygen.</p>
<p>The<strong> Master-Touch MP series</strong> is designed for industrial applications in hazardous areas, while the <strong>Master-Touch MPNH</strong> series is suitable for <strong>Non Hazardous</strong> area applications. Both series feature various models:</p>
<ul>
<li>For insertion and with extraction valve</li>
<li>With threaded, flanged and tri-clamp pipe</li>
<li>With integrated and blind electronics</li>
<li>With integrated electronics and local display</li>
<li>With integrated electronics and remote display</li>
</ul>
<p><strong>SPECIFICATIONS</strong></p>
<ul>
<li>Linearized exits 4-20 mA and 0-5 VdC</li>
<li>Protocols: RS232 &amp; RS485 Modbus RTU, Hart®</li>
<li>Accuracy (T<sub>ref</sub>21°C) ± [1% reading + (0.5% + 0.02% / ° C scale)] &#8211; Repeatability ± 0.2% full scale</li>
<li>Response time ≈ 1 sec</li>
<li>Turn Down minimum 100: 1</li>
<li>Continuous load loss: null</li>
<li>Appropriate environmental temperature for the electronics -40 &lt;T &lt;+ 85 ° C</li>
<li>Sensors in contact with the process in SS316 or Hastelloy</li>
<li>MP series: housing in painted cast aluminum NEMA 4X IP66</li>
<li>MPNH series: housing in ABS and polycarbonate NEMA 4X IP66</li>
<li>Certification CE ATEX 0344 II 2 GD Ex d IIB + H2; IP66; T2 or T3 or T4 (where applicable)</li>
<li>Certification CE PED (where applicable)</li>
<li>Optional LightWire <img src="https://s.w.org/images/core/emoji/14.0.0/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Communicator for infrared connection between PC and flow meter, to program, check and set without removing the case</li>
<li>Provided with E-Logger <img src="https://s.w.org/images/core/emoji/14.0.0/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> software to fully manage the flow meter by changing the parameters, recording the values, totalizing the flows, exporting the heats and even putting them in graphical form.</li>
</ul>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-master-touch-mp-mpnh/">Thermal Mass Flowmeters – Master-Touch MP – MPNH</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Turbine flowmeters</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/turbine-flowmeters/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:39 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6569</guid>

					<description><![CDATA[<p>Tecnova ht is able to provide a wide range of reliable and efficient solutions, adapted to various types of applications. The turbine flowmeters are on the market since 1925 and they have proved their worth in various applications, including the harsh ones in the Oil &#38; Gas sector. The turbine flowmeter Tecnova ht can operate at [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/turbine-flowmeters/">Turbine flowmeters</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Tecnova ht</strong> is able to provide a wide range of reliable and efficient solutions, adapted to various types of applications.</p>
<p>The <strong>turbine flowmeters</strong> are on the market since 1925 and they have proved their worth in various applications, including the harsh ones in the Oil &amp; Gas sector.</p>
<p>The <strong>turbine flowmeter Tecnova ht</strong> can operate at very high temperatures and pressures. It is intended for applications involving liquid, gaseous and cryogenic materials (never steam).</p>
<p>The flowmeters do not require maintenance and can be made of different materials, such as Carbon Steel, Stainless Steel, Duplex, Hastelloy.</p>
<p>The <strong>turbine flowmeter Tecnova ht</strong> brings many advantages and guarantees a refined mechanics and high precision with an immediate response time.</p>
<p>The <strong>turbine flowmeter </strong>calculates the flow rate of the fluid in relation to its speed: thanks to the thrust of the fluid, the rotation speed is linear to the flow. The coil is equipped with a permanent magnet and, once the passage of the blade is detected, the pick-up sends a pulse. The volume of the poured fluid is indicated by the total of the pulses. Their frequency also indicates the flow rate: Q = K * nmt</p>
<p><strong>Q</strong> = volumetric flow rate<br />
<strong>K</strong> = Constant of Proportionality of each turbine (k-factor)<br />
<strong>Nmt</strong> = number of turns</p>
<p>The K constant, indicated on the meter body and on the calibration certificates, is calculated through the calibration of the flowmeter.</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/turbine-flowmeters/">Turbine flowmeters</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mass flowmeters Coriolis -AQ-Rate 300 series</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/mass-flowmeters-coriolis-aq-rate-300-series/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:39 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6570</guid>

					<description><![CDATA[<p>The mass flowmeters Coriolis differ from other technologies as they do not measure the actual volumetric flow rate or speed of the fluid, but the mass flow rate flowing in the pipe (kg / hr). The flowmeters of the new AQ-Rate 300 series are instruments for measuring the mass of hydrocarbon and fuel oil in [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/mass-flowmeters-coriolis-aq-rate-300-series/">Mass flowmeters Coriolis -AQ-Rate 300 series</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>mass flowmeters Coriolis</strong> differ from other technologies as they do not measure the actual volumetric flow rate or speed of the fluid, but the mass flow rate flowing in the pipe (kg / hr).</p>
<p>The<strong> flowmeters of the new AQ-Rate 300 series</strong> are instruments for measuring the mass of hydrocarbon and fuel oil in the liquid phase.</p>
<p>These <strong>flowmeters </strong>are provided with flanged connections splitting internally into two smaller tubes identical to one another and shaped like a V. Their resonance frequencies are induced in the opposite direction between them. At the passage of the fluid in the tubes, the input section of the V-shape starts vibrating at the same frequency of the output section, but with a time delta called mismatch. The magnitude of this mismatch is proportional to the mass flow through the tube, while the density of the liquid in question is given by the frequency of the complete system. It is also possible to obtain the volumetric measurement by dividing the mass flow for the density.</p>
<p>The <strong>meters of the AQ-Rate 300 series</strong> are equipped with integrated totaliser transmitter, replaceable by remote electronics for applications in harsh environments, high temperatures or strong vibrations.</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/mass-flowmeters-coriolis-aq-rate-300-series/">Mass flowmeters Coriolis -AQ-Rate 300 series</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>BARTON® CAMERON Precision Liquid Turbine flowmeters – Model 7000</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/barton-cameron-precision-liquid-turbine-flowmeters-model-7000/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:39 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6564</guid>

					<description><![CDATA[<p>Cameron’s BARTON® 7000 series liquid turbine meters are designed for a broad range of precise liquid measurement applications. Based on more than 40 years of turbine manufacturing experience, this built-to-order series features a range of sizes, materials, bearing systems, and options. FEATURES Linearity (BARTON Models 7100 and 7200) ± 1% of reading over flow range [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/barton-cameron-precision-liquid-turbine-flowmeters-model-7000/">BARTON® CAMERON Precision Liquid Turbine flowmeters – Model 7000</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Cameron’s BARTON® 7000 series liquid turbine meters</strong> are designed for a broad range of precise liquid measurement applications. Based on more than 40 years of turbine manufacturing experience, this built-to-order series features a range of sizes, materials, bearing systems, and options.</p>
<hr />
<p><strong>FEATURES</strong></p>
<p><strong>Linearity (BARTON Models 7100 and 7200)</strong></p>
<ul>
<li>± 1% of reading over flow range for meters smaller than 1-in.</li>
<li>± 0.25% of reading over flow range for meters 1 in. and larger</li>
<li>± 0.15% of reading over limited ranges (1 in. and larger meters contact factory for details)</li>
</ul>
<p><strong> Linearity (BARTON Model 7300)</strong></p>
<ul>
<li>± 0.25% of reading over flow range</li>
<li>± 0.15% of reading over limited ranges (contact factory for details)</li>
</ul>
<p><strong>Repeatability </strong></p>
<p>± 0.02% of reading</p>
<p><strong>Symmetrical bi-directional design.</strong> Ideal for reverse flow applications, where flow capacities are the same in either direction. Electronic options provide instantaneous flow direction sensing.</p>
<p><strong>High quality bearings.</strong> Model 7100/7300 meters come standard with wear-resistant tungsten carbide sleeve bearings, and model 7200 meters are designed with self-lubricating, precision stainless steel bearings with dry lubricant impregnated ball separators.</p>
<hr />
<p><strong>ACCESSORIES</strong></p>
<p>Cameron offers a broad range of accessories and companion electronics for use with the BARTON 7000 series turbine meter, including:</p>
<ul>
<li>Meter runs</li>
<li>Pre-amplifiers</li>
<li>Totalizers</li>
<li>Flow computers</li>
<li>Connectors and cables Companion electronics can be supplied to meet explosion-proof or intrinsic safety requirements.</li>
</ul>
<hr />
<p><img decoding="async" loading="lazy" class="size-full wp-image-1177" src="http://fortekeu.wpengine.com/wp-content/uploads/2017/02/BARTON_7100-MODEL-SELECTION.jpg" alt="BARTON® CAMERON 7100 - Model selection" width="616" height="368" /></p>
<p><img decoding="async" loading="lazy" class="size-full wp-image-1178" src="http://fortekeu.wpengine.com/wp-content/uploads/2017/02/BARTON_7200-7300_MODEL-SELECTION.jpg" alt="BARTON® CAMERON 7200 - 7300 Model selection" width="617" height="508" /></p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/barton-cameron-precision-liquid-turbine-flowmeters-model-7000/">BARTON® CAMERON Precision Liquid Turbine flowmeters – Model 7000</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermal Mass Flowmeters &#8211; VOLUMASS™ Meters</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-volumass-meters/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:39 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6565</guid>

					<description><![CDATA[<p>The Thermal Mass Flowmeters measure the mass flow rate of the flowing gas without the aid of moving parts and are not susceptible to variations in pressure or process temperature. Thanks to the Thermal Mass technology, the Thermal Mass Flowmeters can measure the mass of the gas flow per unit time, without the influence of temperature and pressure on the meter. Each Thermal [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-volumass-meters/">Thermal Mass Flowmeters &#8211; VOLUMASS™ Meters</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The<strong> Thermal Mass Flowmeters</strong> measure the mass flow rate of the flowing gas without the aid of moving parts and are not susceptible to variations in pressure or process temperature.</p>
<p>Thanks to the Thermal Mass technology, the <strong>Thermal Mass Flowmeters can measure</strong> the mass of the gas flow per unit time, without the influence of temperature and pressure on the meter.</p>
<p>Each <strong>Thermal Mass Flowmeter </strong>is calibrated to the required flow rate and pre-compensated for temperature.</p>
<p>The t<strong>Thermal Mass Flowmeters</strong> are suitable for applications involving, among others: Argon, Nitrogen, Biogas, CO2, Digester, Helium, Gas Torch, hydrogen, hydrocarbon mixtures, Methane, Natural Gas, Oxygen.</p>
<p>The<strong> VOLUMASS<img src="https://s.w.org/images/core/emoji/14.0.0/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> series</strong> has been designed by Eldridge for less demanding applications in a safe area. This series shares the same measuring principle of Master Touch  and is suitable to every budget. The meters of this series can be equipped with enclosure rated NEMA 4X IP66 in cast aluminum or ABS, blindly or with large display.<br />
The <strong>VOLUMASS<img src="https://s.w.org/images/core/emoji/14.0.0/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Meters</strong>, factory calibrated and suitable for applications involving air, nitrogen, biogas, helium, CO2, etc., Have an accuracy of ± [2% reading + (0.5% of full scale + 0.05% / °C )].</p>
<p>&nbsp;</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-volumass-meters/">Thermal Mass Flowmeters &#8211; VOLUMASS™ Meters</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermal Mass Flowmeters &#8211; 9000MP Multipoint System series</title>
		<link>https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-9000mp-multipoint-system-series/</link>
		
		<dc:creator><![CDATA[admin-fortek]]></dc:creator>
		<pubDate>Thu, 27 Jan 2022 21:53:39 +0000</pubDate>
				<guid isPermaLink="false">https://fortek.marcoperez.consulting/?post_type=product&#038;p=6566</guid>

					<description><![CDATA[<p>&#160; &#160; The Thermal Mass Flowmeters measure the mass flow rate of the flowing gas without the aid of moving parts and are not susceptible to variations in pressure or process temperature. Thanks to the Thermal Mass technology, the Thermal Mass Flowmeters can measure the mass of the gas flow per unit time, without the influence of temperature and pressure on the meter. [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-9000mp-multipoint-system-series/">Thermal Mass Flowmeters &#8211; 9000MP Multipoint System series</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The<strong> Thermal Mass Flowmeters</strong> measure the mass flow rate of the flowing gas without the aid of moving parts and are not susceptible to variations in pressure or process temperature.</p>
<p>Thanks to the Thermal Mass technology, the <strong>Thermal Mass Flowmeters can measure</strong> the mass of the gas flow per unit time, without the influence of temperature and pressure on the meter.</p>
<p>Each <strong>Thermal Mass Flowmeter </strong>is calibrated to the required flow rate and pre-compensated for temperature.</p>
<p>The t<strong>Thermal Mass Flowmeters</strong> are suitable for applications involving, among others: Argon, Nitrogen, Biogas, CO2, Digester, Helium, Gas Torch, hydrogen, hydrocarbon mixtures, Methane, Natural Gas, Oxygen.</p>
<p>The <strong>9000MP Multipoint System series </strong>has been specifically designed by Eldridge to ensure high reliability in measurements of chimney emissions where it is impossible to install a simple differential pressure darcy.</p>
<p>The<strong> 9000MP Multipoint Mass Flow Systems</strong> are designed to measure air and gas flow in systems where two or more sensing points are required due to large cross-sectional areas. The typical <strong>9000MP Multipoint System</strong> includes one or more 9000MP Probe and a 9600MP System Control Panel.</p>
<p>L'articolo <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/prodotto/thermal-mass-flowmeters-9000mp-multipoint-system-series/">Thermal Mass Flowmeters &#8211; 9000MP Multipoint System series</a> proviene da <a rel="nofollow" href="https://fortek.marcoperez.consulting/en/">FORTEK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>