{"id":5571,"date":"2022-01-27T22:08:49","date_gmt":"2022-01-27T21:08:49","guid":{"rendered":"https:\/\/fortek.marcoperez.consulting\/?post_type=product&#038;p=5571"},"modified":"2022-05-02T11:46:03","modified_gmt":"2022-05-02T09:46:03","slug":"fh-centrifugal-electric-pumps-en-733-din-24255","status":"publish","type":"product","link":"https:\/\/fortek.marcoperez.consulting\/en\/prodotto\/fh-centrifugal-electric-pumps-en-733-din-24255\/","title":{"rendered":"FH &#8211; Centrifugal electric pumps (EN 733 \u2013 DIN 24255)"},"content":{"rendered":"<p>The <strong>FH centrifugal electric pumps Lowara\u00a0<\/strong>have cast iron body and AISI 316L stainless\u00a0steel, laser-technology welded impeller. They are suitable for pumping hot and cold, moderately\u00a0aggressive liquids.<\/p>\n<p>Available models:<\/p>\n<ul>\n<li>FHE Close-coupled with special motor shaft extension.<\/li>\n<li>FHS With stub shaft and standard motor.<\/li>\n<li>FHF With flexible coupling, adapter, base and standard motor in compliance with EN 733 \u2013 DIN 24255.<\/li>\n<\/ul>\n<hr \/>\n<p><strong>MARKET SECTORS:<\/strong> CIVIL, AGRICULTURAL, INDUSTRIAL<\/p>\n<hr \/>\n<p><strong>APPLICATIONS<\/strong><\/p>\n<ul>\n<li>Handling of clean, chemically non-aggressive water and liquids.<\/li>\n<li>Water supply and pressure boosting.<\/li>\n<li>Irrigation.<\/li>\n<li>Water circulation in air conditioning systems.<\/li>\n<li>Washing systems.<\/li>\n<li>Industry.<\/li>\n<li>Agriculture.<\/li>\n<li>Swimming pools.<\/li>\n<\/ul>\n<hr \/>\n<p><strong>SPECIFICATIONS <\/strong><\/p>\n<p><span style=\"text-decoration: underline;\">PUMP <\/span><\/p>\n<ul>\n<li>Delivery up to 650 m3 \/h, 2 poles. 750 m3 \/h, 4 poles.<\/li>\n<li>Head over 100 m, 2 poles. 60 m, 4 poles.<\/li>\n<li>Temperature of pumped liquid:<\/li>\n<\/ul>\n<ol>\n<li>-20\u00b0C to +85\u00b0C for FH 32, 40, 50, 65, 80 standard version.<\/li>\n<li>-30\u00b0C to +120\u00b0C for FH 100, 125, 150 standard version (65-315 80-315 and 80-400 included).<\/li>\n<li>Upon request, up to +140\u00b0C for FH 100, 125, 150.<\/li>\n<\/ol>\n<ul>\n<li>Maximum operating pressure: 12 bar (PN 12) up to FH 80;\u00a0PN 16 flanges for FH100, 125, 150.<\/li>\n<li>Maximum pressure in pump casing: 12 bar for temperatures up to 120\u00b0C; 10 bar for temperatures ranging from 120\u00b0C to 140\u00b0C.<\/li>\n<li>Wear rings made of AISI 316L stainless steel on impeller front and rear wear plates up to FH80 (65-315, 80-315 and 80-400 excluded).<\/li>\n<li>Mechanical seal according to EN12756 (ex DIN 24960).<\/li>\n<li>Mechanical seal lubricated by internal recirculation of pumped liquid to seal housing for FH 32, 40, 50, 65, 80 (65-315, 80-315 and 80-400 excluded).<\/li>\n<li>Mechanical seal locking pin slot for FH32, 40, 50, 65, 80 (65-315, 80-315 and 80-400 excluded).<\/li>\n<li>Counter-clockwise rotation when loocking at pump from the suction port side.<\/li>\n<li>Impeller: made of AISI 316L stainless steel, laser technology, welded for sizes 32, 40, 50, 65-125, cast iron for sizes 65-160, 65-200, 65-250, 65-315, 80, 100, 125, 150. \u2022 Bronze impeller available on request request (for models normally equipped with cast iron impeller).<\/li>\n<\/ul>\n<p><span style=\"text-decoration: underline;\">MOTOR<\/span><\/p>\n<ul>\n<li>Squirrel cage in short circuit, alumin- um casing, enclosed construction with external ventilation.<\/li>\n<li>Standard supplied IE2\/IE3 motors are compliant with Regulation (EC) no. 640\/2009 and IEC 60034-30.<\/li>\n<li>IP 55 protection.<\/li>\n<li>Class 155 (F) insulation.<\/li>\n<li>Performances according to EN 60034-1.<\/li>\n<li>Continuous duty.<\/li>\n<li>Max. ambient temperature: 40\u00b0C.<\/li>\n<li>Condensation drain plugs on all LOWARA motors.<\/li>\n<li>Standard voltage: Single-phase version 220-240 V, 50 Hz Three-phase version 220-240\/380-415 V, 50 Hz for powers up to 3 kW; 380-415\/660-690 V, 50 Hz for powers above 3 kW.<\/li>\n<\/ul>\n<hr \/>\n<p><strong>CONSTRUCTION CHARACTERISTICS<\/strong><\/p>\n<ul>\n<li>Cast iron centrifugal pump with end suction and radial discharge ports.<\/li>\n<li>Hydraulic sizes and nominal diameter (DN) of suction and discharge ports according to EN 733 (ex DIN 24255).<\/li>\n<li>Flanges according to EN 1092-2 (ex UNI 2236) and DIN 2532.<\/li>\n<li>Back pull-out design (impeller, adaptor and motor can be extracted without disconnecting the pump body from the pipes).<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The FH centrifugal electric pumps Lowara\u00a0have cast iron body and AISI 316L stainless\u00a0steel, laser-technology welded impeller. They are suitable for pumping hot and cold, moderately\u00a0aggressive liquids. Available models: FHE Close-coupled with special motor shaft extension. FHS With stub shaft and standard motor. FHF With flexible coupling, adapter, base and standard motor in compliance with EN [&hellip;]<\/p>\n","protected":false},"featured_media":5617,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"product_cat":[599],"product_tag":[728],"_links":{"self":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product\/5571"}],"collection":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/comments?post=5571"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media\/5617"}],"wp:attachment":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media?parent=5571"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=5571"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=5571"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}