{"id":6138,"date":"2022-01-27T22:21:11","date_gmt":"2022-01-27T21:21:11","guid":{"rendered":"https:\/\/fortek.marcoperez.consulting\/?post_type=product&#038;p=6138"},"modified":"2022-05-02T11:41:32","modified_gmt":"2022-05-02T09:41:32","slug":"wafer-disc-check-valve-r-series","status":"publish","type":"product","link":"https:\/\/fortek.marcoperez.consulting\/en\/prodotto\/wafer-disc-check-valve-r-series\/","title":{"rendered":"Wafer disc check valve &#8211; R series"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">The <\/span><b>WAFER swing or tilting disc check valve of the R<\/b> <b>series<\/b><span style=\"font-weight: 400;\"> can be manufactured with flanges on request. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">The <\/span><b>WAFER swing or tilting disc check valve of the R series <\/b><span style=\"font-weight: 400;\">has a one\u2010piece cast body which provides easy evacuation of solid particles contained in the fluid. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">The <\/span><b>WAFER swing or tilting disc check valve of the R series<\/b><span style=\"font-weight: 400;\"> has an arrow on the body indicating the flow direction. It can be supplied with auxiliary spring to obtain faster sealing. For high water loads or large valve diameters hydraulic damping systems can be incorporated which reduce the valve\u2019s impact in the sealing. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">The <\/span><b>WAFER swing or tilting disc check valve of the R series<\/b><span style=\"font-weight: 400;\"> allows the fluid to flow through in one direction, it is opened by the fluid passing through and it closes due to the weight of the disc and the return of the fluid. <\/span><\/p>\n<hr \/>\n<p><b>General Applications<\/b><\/p>\n<p><span style=\"font-weight: 400;\">This valve is suitable for liquids that contain a maximum of 5% suspended solids. It is designed for a wide range of applications such as: \u00a0\u00a0<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Paper Industry<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Chemical plants<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Sewage treatment<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Pumping<\/span><\/li>\n<\/ul>\n<p><b>Sizes \u00a0<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">From ND50 to ND1.200<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Larger sizes on request<\/span><\/li>\n<\/ul>\n<p><b> Working Pressure<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">From ND50 to ND600: Maximum PN 64<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">From ND700 to ND1.200: Maximum PN 25<\/span><\/li>\n<\/ul>\n<p><b>Flange connection<\/b><\/p>\n<p><span style=\"font-weight: 400;\"> The standard flange connection is according to DIN PN10. Other flange connections are available on request, such as: <\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u2010 ANSI 150<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u2010 Australian Standard \u00a0\u00a0\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u2010 DIN PN6<\/span><\/p>\n<p><span style=\"font-weight: 400;\"> \u2010DIN PN16<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u2010DIN PN25 <\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u2010 British Standard \u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u2010 JIS Standard<\/span><\/p>\n<p><b>Directives<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Machinery Directive: DIR 2006\/42\/EC (MACHINERY)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Pressure Equipment Directive: DIR 97\/23\/EC (PED) ART.3, P.3<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Potential Explosive Atmospheres Directive: DIR 94\/9\/CE (ATEX) CAT.3 ZONE 2 and 22 GD<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The WAFER swing or tilting disc check valve of the R series can be manufactured with flanges on request. The WAFER swing or tilting disc check valve of the R series has a one\u2010piece cast body which provides easy evacuation of solid particles contained in the fluid. The WAFER swing or tilting disc check valve [&hellip;]<\/p>\n","protected":false},"featured_media":6174,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"product_cat":[646],"product_tag":[741],"_links":{"self":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product\/6138"}],"collection":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/comments?post=6138"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media\/6174"}],"wp:attachment":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media?parent=6138"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=6138"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=6138"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}