{"id":6145,"date":"2022-01-26T19:16:53","date_gmt":"2022-01-27T21:21:12","guid":{"rendered":"https:\/\/fortek.marcoperez.consulting\/?post_type=product&#038;p=6145"},"modified":"2022-05-02T11:51:01","modified_gmt":"2022-05-02T09:51:01","slug":"gemu-618-aseptic-diaphragm-valve","status":"publish","type":"product","link":"https:\/\/fortek.marcoperez.consulting\/en\/prodotto\/gemu-618-aseptic-diaphragm-valve\/","title":{"rendered":"GEM\u00dc 618 aseptic diaphragm valve"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">The<\/span><b> GEM\u00dc 618 2\/2-way aseptic diaphragm valve<\/b><span style=\"font-weight: 400;\"> has a low maintenance motorized actuator with a reversible synchronous motor. Operation takes place via a non-self-locking reduction gear and cam. An integral optical position indicator is standard. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">The<\/span><b> GEM\u00dc 618 2\/2-way aseptic diaphragm valve<\/b><span style=\"font-weight: 400;\"> has an integrated optical position indicator as standard. It is also available without a metal distance piece for applications with lower operating temperatures (only diaphragm size 10).<\/span><\/p>\n<hr \/>\n<p><b>TECHNICAL SPECIFICATIONS<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Connection: Clamp; Spigot; Threaded socket; Threaded spigot<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Actuator: Motorized<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">ATEX<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Explosion protection<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Body material: 1.4435, forged body; 1.4435, investment casting; CW617N (brass)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Max. operating pressure: 6 bar<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Max. media temperature: 100 \u00b0 C<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Min. media temperature: -10 \u00b0 C<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Nominal sizes<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Control valve<\/span><\/li>\n<\/ul>\n<p><b>FEATURES<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Suitable for inert and corrosive liquid and gaseous media <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Insensitive to particulate media <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">The motor will withstand being stalled under full voltage <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Valve body and diaphragm available in various materials and designs<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Suitable for use as a control valve (with integrated control module)<\/span><\/li>\n<\/ul>\n<p><b>ADVANTAGES<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Direct 0\/4 &#8211; 20 mA signal processing (with integrated control module) <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Opening and closing behaviour is independent of the operating pressure<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Hermetic separation between medium and actuator <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Optional flow direction<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Installation for an optimized draining is possible<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The GEM\u00dc 618 2\/2-way aseptic diaphragm valve has a low maintenance motorized actuator with a reversible synchronous motor. Operation takes place via a non-self-locking reduction gear and cam. An integral optical position indicator is standard. The GEM\u00dc 618 2\/2-way aseptic diaphragm valve has an integrated optical position indicator as standard. It is also available without [&hellip;]<\/p>\n","protected":false},"featured_media":4746,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"product_cat":[638],"product_tag":[722],"_links":{"self":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product\/6145"}],"collection":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/comments?post=6145"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media\/4746"}],"wp:attachment":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media?parent=6145"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=6145"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=6145"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}