{"id":6382,"date":"2022-01-26T19:16:51","date_gmt":"2022-01-27T21:22:28","guid":{"rendered":"https:\/\/fortek.marcoperez.consulting\/?post_type=product&#038;p=6382"},"modified":"2022-05-02T11:09:04","modified_gmt":"2022-05-02T09:09:04","slug":"gemu-0324-directly-controlled-3-2-way-pilot-solenoid-valve","status":"publish","type":"product","link":"https:\/\/fortek.marcoperez.consulting\/en\/prodotto\/gemu-0324-directly-controlled-3-2-way-pilot-solenoid-valve\/","title":{"rendered":"GEM\u00dc 0324 &#8211; directly controlled 3\/2-way pilot solenoid valve"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">The <\/span><b>GEM\u00dc 0324 directly controlled 3\/2-way pilot solenoid valve<\/b><span style=\"font-weight: 400;\"> consists of an epoxy encapsulated detachable coil and a plastic body. The electrical connection is made via a plug complying with DIN EN 175301-803 form A or a M12 plug. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">The <\/span><b>GEM\u00dc 0324 directly controlled 3\/2-way pilot solenoid valve<\/b><span style=\"font-weight: 400;\"> is<\/span><span style=\"font-weight: 400;\"> designed for direct mounting (hollow bolt) to pneumatically operated valves or other devices.<\/span><span style=\"font-weight: 400;\"> The body is made of plastic. The coil is plastic encapsulated.<\/span><\/p>\n<hr \/>\n<p><b>Technical specifications<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Connection<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Actuator<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">ATEX<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Explosion protection<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Body material<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Max. operating pressure: 10 bar<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Max. media temperature: 50 \u00b0 C<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Min. media temperature: -10 \u00b0 C<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Nominal sizes<\/span><\/li>\n<\/ul>\n<p><b>Features <\/b><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\">Suitable for the control of chemically inert gases <\/span><\/li>\n<li><span style=\"font-weight: 400;\">Normally closed and Normally open control functions are available<\/span><\/li>\n<\/ul>\n<p><b>Options:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">ATEX version: ATEX-marking (control function 1): <\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">II 2 G Ex mb II T4 <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">II 2 D Ex tD A21 IP65 T130\u00b0C<\/span><\/li>\n<\/ul>\n<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Lockable manual override (control function 1) <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Integrated LED (M12 version) <\/span><\/li>\n<\/ul>\n<p><b>Advantages<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Robust design <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Coil easy to replace <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Option: integrated LED (M12 version) <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Multi-functional application possibilities due to various designs <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Modular battery mounting<\/span><\/li>\n<\/ul>\n<p><a class=\"famiglia\" href=\"http:\/\/fortekeu.wpengine.com\/wp-content\/uploads\/2016\/09\/datasheet_electrovalves_gemu_0322_0324_0326.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet GEM\u00dc 0322\/0324\/0326 &#8211; directly controlled 3\/2-way pilot solenoid valves<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The GEM\u00dc 0324 directly controlled 3\/2-way pilot solenoid valve consists of an epoxy encapsulated detachable coil and a plastic body. The electrical connection is made via a plug complying with DIN EN 175301-803 form A or a M12 plug. The GEM\u00dc 0324 directly controlled 3\/2-way pilot solenoid valve is designed for direct mounting (hollow bolt) [&hellip;]<\/p>\n","protected":false},"featured_media":4718,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"product_cat":[495],"product_tag":[722],"_links":{"self":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product\/6382"}],"collection":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/comments?post=6382"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media\/4718"}],"wp:attachment":[{"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/media?parent=6382"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=6382"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fortek.marcoperez.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=6382"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}